{"product_id":"ph-sensor-s-ph-01a-v2","title":"Industrial pH Sensor (S-pH-01A) V2.0","description":"\u003cdiv data-page-id=\"OF8fdIhkLowYQExTxGBl8nWRgfh\" data-lark-html-role=\"root\" data-docx-has-block-data=\"true\"\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-Lrb9dMn5AoZ2WaxgLpylDpH3gZd\"\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-B2zIdLjUEoq8fTx7OkTlDDQ8ggf\"\u003eThis \u003cstrong\u003eIndustrial pH Sensor\u003c\/strong\u003e \u003cstrong\u003e(S-pH-01A) V2.0 \u003c\/strong\u003emeasures pH levels in soil and water applications ranging from 0 to 14 pH, making it widely applicable in industrial environmental sensing scenarios (e.g. gardening, swimming pools, etc.). Use the sensor with SenseCAP Data Logger for seamless data collection and management.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CRRzdcmhJobpmvxwK2fl0HOSgI2\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CRRzdcmhJobpmvxwK2fl0HOSgI2\"\u003eThis pH Sensor with hook-up wires measures the hydrogen-ion activity in water-based solutions, indicating its acidity or basicity expressed as pH. pH level is an important indicator in many scenarios, especially in monitoring soil conditions and water quality.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MPaCdk3ZPoSQutx0WWwlfFFrgfb\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MPaCdk3ZPoSQutx0WWwlfFFrgfb\"\u003eThis pH Sensor is designed with industry standards. It adopts an international advanced solid dielectric and large-area polytetrafluoroethylene liquid junction, which is not easy to block and convenient for maintenance. Its electrode is IP68, the transmitter is IP65 rated, waterproof in a tight seal, and capable of withstanding long-term constant use in professional scenarios. This pH Sensor comes with a MODBUS-RTU RS485 serial communications protocol and 0~2V Analog Voltage output. It can be easily connected and integrated with other devices such as data loggers, converters, displays, etc. This cost-effective pH sensor features low-power consumption, compact size, portability, and high integration.\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-YnAzdPG4coH87Qx9Adal692ugUW\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-YnAzdPG4coH87Qx9Adal692ugUW\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KVVJdQcq1oAmiZx5knylwnWtg8f\"\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e High accuracy, fast response, good repeatability\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GZVWdjs7to7HDtxHBP0lEY0zgie\"\u003e\n\u003cstrong\u003eUniversal Protocol:\u003c\/strong\u003e MODBUS-RTU RS485 and 0~2V Analog Voltage\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Uzn7dKFP1oRhUnxq4nDlQDrIgvc\"\u003e\n\u003cstrong\u003eWide-range Power Supply:\u003c\/strong\u003e Can be powered with supply voltage within 3.6V ~ 30V\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QJjdd0ks1oVXFoxfMIIlcU1og2c\"\u003e\n\u003cstrong\u003eStrong Robustness:\u003c\/strong\u003e Suitable to be immersed in soil or water for a long time, anti-corrosion\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-SAyldv7rTouU0gxZ73clRpJsgUc\"\u003e\n\u003cstrong\u003eMaintainance-Free:\u003c\/strong\u003e A unique junction efficiently improves the problem of junction clogging\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-V6U6dH5kRo9gxRxyMsjl8qzlgdh\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-V6U6dH5kRo9gxRxyMsjl8qzlgdh\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Iy63d3EVBo3zdbxwcm7lo5PUgrh\"\u003e\n\u003cstrong\u003eProduct Model:\u003c\/strong\u003e S-pH-01A\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-G5Jid1r6zogtUnxNyyWln5wtgMe\"\u003e\n\u003cstrong\u003eOutput Interface: \u003c\/strong\u003eRS-485 MODBUS-RTU\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-LTRfd0OAFosmZgx1t5flqVN9gYc\"\u003e\n\u003cstrong\u003eAnalog Voltage:\u003c\/strong\u003e 0 - 2V\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PfzDd7BE5ovI6HxrcLnldlvWgAb\"\u003e\n\u003cstrong\u003ePower Supply: \u003c\/strong\u003e3.9 - 30 V\/DC\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-IdugdO97kopMrlxZf36lRuinguc\"\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e35mA @ 24V DC\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KRUJdeRZFoToNqxK6eylpMu0g5n\"\u003e\n\u003cstrong\u003eStart-up Time:\u003c\/strong\u003e \u0026lt; 2 seconds\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-UxwQdySjUoh4K5xPS2ElK4YZg3b\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003epH Measurement \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eHigh impedance and isolated input\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 0 ~ 14 pH\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution: \u003c\/strong\u003e0.01 pH\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy: \u003c\/strong\u003e± 0.1 pH\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCan be used for a solution or semi-solid substrate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Nf0Qdc2O4oaROyxhbVylKqEsgZb\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eTemperature Measurement \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e -40 ~ 80°C\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution: \u003c\/strong\u003e0.1°C\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy: \u003c\/strong\u003e+\/-0.5°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Ly0udAeAPo96n5xX8SNlSawEgIb\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eIP Rating \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode: \u003c\/strong\u003eIP68\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter: \u003c\/strong\u003eIP65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GrakdjX9hoDlnHxoOFllnQLpgWg\"\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40℃ ~ 85℃\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-FeW4dqBUro0heYxhuyYl4HLzgLf\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eInstallation \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode: \u003c\/strong\u003e3\/4\"NPT screw threads\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter: \u003c\/strong\u003eMounting hole\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QrLXdtnGZo2ubOxOBMZlTTQ6gSw\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eCable Length \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower and Signal Cable: \u003c\/strong\u003e2 meters (Customizable)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode Cable: \u003c\/strong\u003e5 meters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-DYordIJkJouqwNxOAfplu6uRgSg\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrode: \u003c\/strong\u003eWidth*Diameter 160*30mm\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter: \u003c\/strong\u003e140mm*65mm*50mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-Jny9dwMnEo9W17x43RtlB4ncgGe\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-Jny9dwMnEo9W17x43RtlB4ncgGe\"\u003e\u003cstrong\u003eHardware Overview:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XquwdGgw5oMdKax9DQTl1YpDgCh\"\u003e\u003cstrong\u003eWiring Diagram:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv data-type=\"image\" data-ace-gallery-json='{\"items\":[{\"uuid\":\"12d887ef-cbfa-4409-9361-731fb78430a7\",\"height\":790,\"width\":1920,\"currHeight\":790,\"currWidth\":1920,\"natrualHeight\":790,\"natrualWidth\":1920,\"pluginName\":\"imageUpload\",\"scale\":1,\"src\":\"https%3A%2F%2Finternal-api-drive-stream-sg.larksuite.com%2Fspace%2Fapi%2Fbox%2Fstream%2Fdownload%2Fpreview%2FJ18Hb8qiGoYZS2xcfnOlZPhLguf%2F%3Fpreview_type%3D16\",\"file_token\":\"J18Hb8qiGoYZS2xcfnOlZPhLguf\",\"image_type\":\"image\/webp\",\"size\":18740,\"comments\":[]}]}' class=\"image-uploaded gallery old-record-id-MXK9dVD2LoJQXUxwvxml3MY6gBc\"\u003e\u003cimg src=\"https:\/\/media-cdn.seeedstudio.com\/media\/wysiwyg\/upload\/image_22.png\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-VeuudAaJzortAfxXyprlmDmHguc\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-U22rd5k5PoOjuxxTS5tlwjFJg9c\"\u003e\n\u003cstrong\u003eNote: \u003c\/strong\u003eVersion 1 of this pH Meter\/Sensor supports RS485 protocol and 4~20mA current, which is now retired, and replaced by this current one: Version 2, supporting RS485 protocol and 0~2V analog voltage.\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-S7eAdyGxXouMuPxs2E9lh4x8gNg\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp class=\"heading-2 ace-line old-record-id-S7eAdyGxXouMuPxs2E9lh4x8gNg\"\u003e\u003cstrong\u003eProbe Dimension:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv data-type=\"image\" data-ace-gallery-json='{\"items\":[{\"uuid\":\"bd19aa54-4f91-4634-9021-e05c489836dc\",\"height\":1152,\"width\":1466,\"currHeight\":1152,\"currWidth\":1466,\"natrualHeight\":1152,\"natrualWidth\":1466,\"pluginName\":\"imageUpload\",\"scale\":1,\"src\":\"https%3A%2F%2Finternal-api-drive-stream-sg.larksuite.com%2Fspace%2Fapi%2Fbox%2Fstream%2Fdownload%2Fpreview%2FR3wBbOQ0PoowsbxzTPVlfp2hgRf%2F%3Fpreview_type%3D16\",\"file_token\":\"R3wBbOQ0PoowsbxzTPVlfp2hgRf\",\"image_type\":\"image\/png\",\"size\":342512,\"comments\":[]}]}' class=\"image-uploaded gallery old-record-id-PAUAdjWwfofQabxUmuElhtwDgXc\"\u003e\u003cimg src=\"http:\/\/files.seeedstudio.com\/products\/101990666\/img\/electrode%20dimension.jpg\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-VDQ0dqrA2oSthcxhROXlf8JjgUd\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-VDQ0dqrA2oSthcxhROXlf8JjgUd\"\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli class=\"ace-line ace-line old-record-id-OqZpdYpS0o0cIoxJE4kl40Hxg2b\"\u003eAgriculture\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-G3CKdUwReoCm9PxuxL3lQFzMg0u\"\u003eAnimal Husbandry\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-QgsMdP39foW5e0xyT3HlNr4Wgle\"\u003eForestry and Horticulture\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-Dxr7dMKlooR3wFxMoBFlcusWg6c\"\u003eSewage Treatment\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-FrphdnsZyoILpuxYqjelImLRgT6\"\u003eSwimming Pools and Spas\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-VOvPdkKT1oinadxu37ilGAblg4g\"\u003eScientific Experiments\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-Mro6dhtwLoBwJRxeG1dlD7qKgOh\"\u003eEducational Projects\u003c\/li\u003e\n\u003cli class=\"ace-line ace-line old-record-id-LInNdJJyTo5PsQxH4tplgt0kgPh\"\u003eOther environmental monitoring scenarios\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-DiKAdZhhCoovWdxA8nDltT0sgcf\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-DiKAdZhhCoovWdxA8nDltT0sgcf\"\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QBswdo0S6oUkR7xuz8KlVinNgrd\"\u003e\u003ca data-lark-is-custom=\"true\" href=\"https:\/\/files.seeedstudio.com\/products\/101990666\/res\/RS485%20\u0026amp;%200-2V%20pH%20Sensor%20(S-pH-01)%20-%20User%20Guide%20v2.0.pdf\"\u003eUser Guide for RS485 \u0026amp; 0-2V Analog Voltage pH Sensor (S-pH-01) - v2.0\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-GzcUd95DlokrGZxEunIlvwqAgld\"\u003e\u003ca data-lark-is-custom=\"true\" href=\"https:\/\/files.seeedstudio.com\/products\/101990666\/res\/RS485%20\u0026amp;%204-20mA%20Current%20pH%20Sensor%20User%20Manual-S-pH-01.pdf\"\u003eUser Manual for the Industrial pH Meter\/ Sensor Modbus-RTU RS485 \u0026amp; 4~20mA Current (S-pH-01A)\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Rm9GdrNRxo1ZhvxN4TmlHyJFghg\"\u003e\u003ca data-lark-is-custom=\"true\" href=\"http:\/\/files.seeedstudio.com\/products\/101990666\/res\/RS485%20\u0026amp;%204-20mA%20Current%20pH%20Sensor%20(S-pH-01)-Datasheet.pdf\"\u003eDatasheet for the Industrial pH Meter\/ Sensor Modbus-RTU RS485 \u0026amp; 4~20mA Current (S-pH-01A)\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JcPBdXnR8onIavxIUFJljLj6gWe\"\u003e\u003ca data-lark-is-custom=\"true\" href=\"https:\/\/files.seeedstudio.com\/products\/101990666\/res\/pH_sensor_Calibration.pdf\"\u003epH Sensor Calibration\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-RN9Qd1izHoPFk3xIbrwlbnOAgJe\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-RN9Qd1izHoPFk3xIbrwlbnOAgJe\"\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PzzOdou3GoikPbxV9A4luTiIgKd\"\u003e1x Industrial pH Sensor with hook-up wires\u003c\/div\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-PMpgd4DHzoqkTHxK8bWltWG6gRc\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"heading-2 ace-line old-record-id-PMpgd4DHzoqkTHxK8bWltWG6gRc\"\u003e\u003cstrong\u003eFAQ:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-RlJ6dRTTNoqzvrxOXkPlP9TMg6T\"\u003e\n\u003cstrong\u003eQ: \u003c\/strong\u003eIs it factory calibrated? How to calibrate?\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-MA5bdvZi8ole5lxonNulTfHGglh\"\u003e\n\u003cstrong\u003eA: \u003c\/strong\u003eYes, the device is fully calibrated prior to shipment from the factory.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-CFL8dSFQiowurrx5ouplBpLygBc\"\u003eAbout calibration, please refer to the document: \u003ca data-lark-is-custom=\"true\" href=\"https:\/\/raw.githubusercontent.com\/Jenkinlu001\/SenseCAP\/master\/PH10-AppNote-PH%20Calibration%20by%20Modbus%20Command.doc\"\u003eraw.githubusercontent.com\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-EwHYdaz1ZofVO2xC9PKlPQUIgkf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-ELzOdjgjWobFALxW0tblvC69gde\"\u003e\n\u003cstrong\u003eQ:\u003c\/strong\u003e Why is the temperature output from the sensor inaccurate?\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-PXW6dXzh8oimOwxvOAflbVbKgFc\"\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e PH electrode itself has no temperature sensor, the temperature is the plate temperature sensor; If necessary, you can access the NTC (10K, 3950) thermistor temperature sensor.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-XNE4dfCMVo5Hvyx2hUKld1BqgXf\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-NYl8dAmiroavgCxwDu9lHEOIg9g\"\u003e\n\u003cstrong\u003eQ: \u003c\/strong\u003eCan the sensor be used in soil? How to install?\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JabEdLe5xoiaFQxs1eQlhFgNgqf\"\u003e\n\u003cstrong\u003eA: \u003c\/strong\u003eYes, Yes, the principle is still to measure the pH in the soil moisture, so it will be affected by the soil moisture, and the drier the soil, the greater the error.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-JajndwsRsoGQbSxtIRflsF8sg6c\"\u003eInstallation method: Dig out a pit, fill the pit with some water, stir the soil into a slurry, and then place the sensor glass probe. Be careful not to overexert yourself and avoid hard objects such as stones, otherwise the probe will be damaged.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Others","offers":[{"title":"Default Title","offer_id":43948430295231,"sku":"MLE06277","price":9499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE06277_2_a2cacbd0-902e-4b91-b2d7-790a0ddb8df3.jpg?v=1749793060","url":"https:\/\/makerlab.ph\/products\/ph-sensor-s-ph-01a-v2","provider":"Makerlab PH","version":"1.0","type":"link"}