{"product_id":"atlas-scientific-dissolved-oxygen-kit","title":"Atlas Scientific Dissolved Oxygen Kit | Kit-103DX","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAtlas Scientific EZO-\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e Kit\u003c\/strong\u003e gives you everything you need to take high accuracy, interference-free readings. Once you become familiar with electrochemical sensing, it will be easy for you to streamline your design and buy only the components that work for you.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis Dissolved Oxygen Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely\u003c\/strong\u003e\u003c\/em\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEZO™ Dissolved Oxygen Circuit\u003c\/li\u003e\n\u003cli\u003eLab Grade Dissolved Oxygen Probe\u003c\/li\u003e\n\u003cli\u003e30ml bottle of Electrolyte Solution\u003c\/li\u003e\n\u003cli\u003e20ml Zero Dissolved Oxygen calibration solution pouches\u003cbr\u003e(used to confirm that the D.O. probe is working properly)\u003c\/li\u003e\n\u003cli\u003eElectrically Isolated EZO™ Carrier Board\u003c\/li\u003e\n\u003cli\u003eSyringe\u003c\/li\u003e\n\u003cli\u003eCarrier Board dimensions\n\u003cul\u003e\n\u003cli\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 25 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"email-link\" id=\"download-files\"\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/LG_DO_probe.pdf\" target=\"_blank\"\u003eLab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVideos:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-DO-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved_oxygen-footprint.zip\" target=\"_blank\"\u003eDissolved Oxygen. CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x EZO™ Dissolved Oxygen Circuit\u003c\/li\u003e\n\u003cli\u003e1x Lab Grade Dissolved Oxygen Probe\u003c\/li\u003e\n\u003cli\u003e1x 30ml bottle of Electrolyte Solution\u003c\/li\u003e\n\u003cli\u003e3x 20ml Zero Dissolved Oxygen calibration solution pouches\u003cbr\u003e(used to confirm that the D.O. probe is working properly)\u003c\/li\u003e\n\u003cli\u003e1x Electrically Isolated EZO™ Carrier Board\u003c\/li\u003e\n\u003cli\u003e1x Syringe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42290943787199,"sku":"MLE00174","price":35499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00174_a3498bd5-b632-4418-baed-720dc03a1e3a.jpg?v=1749712839","url":"https:\/\/makerlab.ph\/products\/atlas-scientific-dissolved-oxygen-kit","provider":"Makerlab PH","version":"1.0","type":"link"}