{"title":"Atlas Scientific","description":"\u003ca href=\"https:\/\/www.makerlab-electronics.com\/collections\/atlas-scientific\" title=\"Atlas Scientific\"\u003e\u003cem data-mce-fragment=\"1\"\u003eAtlas Scientific's\u003c\/em\u003e\u003c\/a\u003e\u003cspan data-mce-fragment=\"1\"\u003e off the shelf product line delivers laboratory grade accuracy to any device imaginable.\u003c\/span\u003e","products":[{"product_id":"atlas-scientific-dissolved-oxygen-kit","title":"Atlas Scientific Dissolved Oxygen Kit | Kit-103DX","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAtlas Scientific EZO-\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e Kit\u003c\/strong\u003e gives you everything you need to take high accuracy, interference-free readings. Once you become familiar with electrochemical sensing, it will be easy for you to streamline your design and buy only the components that work for you.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis Dissolved Oxygen Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely\u003c\/strong\u003e\u003c\/em\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEZO™ Dissolved Oxygen Circuit\u003c\/li\u003e\n\u003cli\u003eLab Grade Dissolved Oxygen Probe\u003c\/li\u003e\n\u003cli\u003e30ml bottle of Electrolyte Solution\u003c\/li\u003e\n\u003cli\u003e20ml Zero Dissolved Oxygen calibration solution pouches\u003cbr\u003e(used to confirm that the D.O. probe is working properly)\u003c\/li\u003e\n\u003cli\u003eElectrically Isolated EZO™ Carrier Board\u003c\/li\u003e\n\u003cli\u003eSyringe\u003c\/li\u003e\n\u003cli\u003eCarrier Board dimensions\n\u003cul\u003e\n\u003cli\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 25 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"email-link\" id=\"download-files\"\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/LG_DO_probe.pdf\" target=\"_blank\"\u003eLab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVideos:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-DO-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved_oxygen-footprint.zip\" target=\"_blank\"\u003eDissolved Oxygen. CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x EZO™ Dissolved Oxygen Circuit\u003c\/li\u003e\n\u003cli\u003e1x Lab Grade Dissolved Oxygen Probe\u003c\/li\u003e\n\u003cli\u003e1x 30ml bottle of Electrolyte Solution\u003c\/li\u003e\n\u003cli\u003e3x 20ml Zero Dissolved Oxygen calibration solution pouches\u003cbr\u003e(used to confirm that the D.O. probe is working properly)\u003c\/li\u003e\n\u003cli\u003e1x Electrically Isolated EZO™ Carrier Board\u003c\/li\u003e\n\u003cli\u003e1x Syringe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42290943787199,"sku":"MLE00174","price":35499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00174_a3498bd5-b632-4418-baed-720dc03a1e3a.jpg?v=1749712839"},{"product_id":"basic-ezo-inline-voltage-isolator","title":"Atlas Basic EZO™ Inline Voltage Isolator | BE-IVI","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Atlas Scientific Basic EZO™ Inline Voltage Isolator ensures reliable and accurate sensor measurements by effectively isolating voltage signals, providing enhanced stability and protection for sensitive instrumentation in various applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Input: 3.0V - 5.0V\u003c\/li\u003e\n\u003cli\u003eData Input: UART 12C and SMBus\u003c\/li\u003e\n\u003cli\u003eMax Data Rate: 1MHz\u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: 5V - 16.3 mA; 3.3V - 20 mA\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 3.7V ± .07\u003c\/li\u003e\n\u003cli\u003eCircuit Dimensions: 13.97mm X 20.16mm (0.55\" X0.79\")\u003c\/li\u003e\n\u003cli\u003eWeight: 3.0V - 5.0Weight: 1.76 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/basic-ezo-inline-voltage-isolator.pdf\" target=\"_blank\"\u003eBasic EZO™ Inline Voltage Isolator Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/mini_iso.zip\" target=\"_blank\"\u003eBasic EZO™ Inline Voltage Isolator Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/BE-IVI.zip\" target=\"_blank\"\u003eBasic EZO™ Inline Voltage Isolator 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42290972393663,"sku":"MLE00719","price":1400.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00719_2.jpg?v=1749717061"},{"product_id":"atlas-scientific-ph-kit","title":"Atlas Scientific pH Kit | KIT-101P","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. The\u003cstrong\u003e Atlas Scientific EZO-pH Kit \u003c\/strong\u003egives you everything you need to take high accuracy, interference-free readings. Once you become familiar with electrochemical sensing, it will be easy for you to streamline your design and buy only the components that work for you.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This pH Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifiations:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eEZO™ pH Circuit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eDouble junction silver \/ silver chloride Gen 3 Lab Grade pH Probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e20ml calibration solution pouches (2x pH 4, 2x pH 7 and 2x pH 10)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e20ml pH storage solution pouch\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eElectrically Isolated EZO™ Carrier Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eCarrier Board dimensions: 56.2mm x 32mm (2.2″ x 1.2″)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eWeight: 25 grams\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv id=\"download-files\" class=\"email-link\"\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ pH Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_probe.pdf\" target=\"_blank\"\u003eGen 3 Lab Grade pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cstrong\u003eDocuments:\u003c\/strong\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph_soil.pdf\" target=\"_blank\"\u003eHow to measure the pH of soil\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ph-wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cstrong\u003eDownloads:\u003c\/strong\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-pH-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-pH-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-pH-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\u003cstrong\u003e3D File:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph-footprint.zip\" target=\"_blank\"\u003epH CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"email-link\"\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1x EZO™ pH Circuit\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1x Double junction silver \/ silver chloride Gen 3 Lab Grade pH Probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e6x 20ml calibration solution pouches (2x pH 4, 2x pH 7 and 2x pH 10)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1x 20ml pH storage solution pouch\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e1x Electrically Isolated EZO™ Carrier Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"image04\"\u003e\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42291003490495,"sku":"MLE01584","price":16499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE01584.jpg?v=1749719655"},{"product_id":"atlas-scientific-orp-kit","title":"Atlas Scientific Surveyor™ Analog ORP Kit | KIT-104O","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAtlas Scientific Surveyor™ ORP Kit \u003c\/strong\u003eis a low-cost solution for engineers who are looking for a simple monitoring solution with a basic analog output. This kit comes with everything you need to get started. The Atlas Scientific Surveyor™ ORP kit gives you the same sensing capabilities found in handheld disposable ORP meters but lasts a hell of a lot longer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis ORP Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Surveyor™ Analog ORP Sensor \/ Meter\u003c\/li\u003e\n\u003cli\u003e1x Consumer Grade ORP Probe\u003c\/li\u003e\n\u003cli\u003e1x 20ml ORP calibration solution pouch (225mV)\u003c\/li\u003e\n\u003cli\u003eSurveyor™ dimensions\n\u003cul\u003e\n\u003cli\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 15 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"downloads\"\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-ORP-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog ORP Sensor \/ Meter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/consumer-grade-ORP-probe.pdf\" target=\"_blank\"\u003eConsumer Grade ORP Probe Datasheet\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-ORP-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog ORP Sensor \/ Meter 3D model (*step)\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Surveyor™ Analog ORP Sensor \/ Meter\u003c\/li\u003e\n\u003cli\u003e1x Consumer Grade ORP Probe\u003c\/li\u003e\n\u003cli\u003e1x 20ml ORP calibration solution pouch (225mV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42291003687103,"sku":"MLE00175","price":12000.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00175_5.jpg?v=1749714006"},{"product_id":"atlas-gravity-analog-ph-kit","title":"Atlas Scientific Surveyor™ Analog pH Kit | KIT-103P","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e(Previously known as the Gravity Analog pH Kit)\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Atlas Scientific Surveyor™ pH Kit low-cost solution for engineers who are looking for a simple monitoring solution with a basic analog output. This kit comes with everything you need to get started. The Atlas Scientific Surveyor™ pH kit gives you the same sensing capabilities found in handheld disposable pH meters but lasts a hell of a lot longer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This pH Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector\u003cem\u003e\u003cstrong\u003e indefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSurveyor™ dimensions\u003c\/li\u003e\n\u003cli\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 15 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-pH-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog pH Sensor \/ Meter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/consumer-grade-pH-probe.pdf\" target=\"_blank\"\u003eConsumer Grade pH Probe Datasheet\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-pH-datasheet.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph_soil.pdf\" target=\"_blank\"\u003eHow to measure the pH of soil\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-pH-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog pH Sensor \/ Meter 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Surveyor™ Analog pH Sensor \/ Meter    \u003c\/li\u003e\n\u003cli\u003e1x Double junction – Silver \/ silver chloride Consumer Grade pH Probe    \u003c\/li\u003e\n\u003cli\u003e3x 20ml Atlas Scientific calibration solutions pouches (pH 4, 7 and 10)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42291055952063,"sku":"MLE01651","price":4990.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE01651.jpg?v=1749793614"},{"product_id":"atlas-scientific-electrical-conductivity-kit-k-1-0","title":"Atlas Scientific Electrical Conductivity Kit K 1.0 | EC-KIT-1.0","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAtlas Scientific K1 EZO-\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eConductivity Kit\u003c\/strong\u003e is perfect measuring water with a conductivity range from 10µs to 100,000µs. That means this kit is perfect for environmental monitoring, hydroponics, and both freshwater and saltwater aquariums.  \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Surface: Platinum black coated platinum\u003c\/li\u003e\n\u003cli\u003eBody material: Epoxy\u003c\/li\u003e\n\u003cli\u003eMax Temperature: 0-70 Degrees C\u003c\/li\u003e\n\u003cli\u003eMax PSI: 1379 kPa (200PSI)\u003c\/li\u003e\n\u003cli\u003eConductivity readings +\/- 2µs\/cm\u003c\/li\u003e\n\u003cli\u003eFull Conductivity range from 0.55 µs\/cm to 500,000+ µs\/cm\u003c\/li\u003e\n\u003cli\u003eTemperature dependent or temperature independent readings\u003c\/li\u003e\n\u003cli\u003eTotal dissolved solids (TDS) referenced to KCL\u003c\/li\u003e\n\u003cli\u003eSalinity is derived from the Practical Salinity Scale (PSS-78)\u003c\/li\u003e\n\u003cli\u003eData output is a comma separated string: µs, TDS, Salinity\u003c\/li\u003e\n\u003cli\u003eSingle reading or continuous reading modes\u003c\/li\u003e\n\u003cli\u003eSimple RS-232 connectivity (voltage swing 0-5v)\u003c\/li\u003e\n\u003cli\u003eSimple instruction set consisting of only 6 (not including calibration) commands\u003c\/li\u003e\n\u003cli\u003e3.3V - 5V operational voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x EZO™ Conductivity Circuit\u003c\/li\u003e\n\u003cli\u003e1x Conductivity Probe: 5 µS\/cm to 200,000 µS\/cm\u003c\/li\u003e\n\u003cli\u003e1x Electrically Isolated EZO™ Carrier Board\u003c\/li\u003e\n\u003cli\u003e4x 20ml calibration solution pouches (2x 12,880µS and 2x 80,000µS)\u003c\/li\u003e\n\u003cli\u003eCarrier Board dimensions\n\u003cul\u003e\n\u003cli\u003e56.2mm x 32mm (2.2? x 1.2?)\u003c\/li\u003e\n\u003cli\u003eWeight: 25 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eData Sheets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_K_1.0_probe.pdf\" target=\"_blank\"\u003eConductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-EC-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D File:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\"\u003eConductivity CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEZO™ Conductivity Circuit\u003c\/li\u003e\n\u003cli\u003ePlatinum Conductivity Sensor (K=1.0)\u003c\/li\u003e\n\u003cli\u003e2 x 125ml (4oz) calibration solutions\u003c\/li\u003e\n\u003cli\u003eFemale BNC connector\u003c\/li\u003e\n\u003cli\u003eBNC connector breakout board\u003c\/li\u003e\n\u003cli\u003eConductivity Circuit decal\u003c\/li\u003e\n\u003cli\u003e1 PWR-ISO\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42292814086335,"sku":"MLE00173","price":18990.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00173.jpg?v=1749712015"},{"product_id":"lab-grade-ph-probe","title":"Atlas Lab Grade pH Probe | ENV-40-pH","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis Atlas Scientific Lab Grade pH probe is our highest accuracy pH probe. The internal double junction lets you read the pH of protein-rich solutions without damaging the probe. The green Vanadium III tip is a hydrogen amplifier, reducing noise and increasing reading stability. A Tyvek™ junction connects the pH probe to the outside world. Because Tyvek™ resists water flow, the internal electrolyte is held in the probe longer, leading to less frequent recalibrations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This pH Probe can be\u003cem\u003e\u003cstrong\u003e fully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSilver \/ silver chloride\u003c\/li\u003e\n\u003cli\u003eReads: pH\u003c\/li\u003e\n\u003cli\u003eRange: 0 ? 14\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/– 0.002\u003c\/li\u003e\n\u003cli\u003eConnector: Male BNC\u003c\/li\u003e\n\u003cli\u003eResolution: +\/- 0.0001\u003c\/li\u003e\n\u003cli\u003eResponse time: 95% in 1s\u003c\/li\u003e\n\u003cli\u003eMax pressure: 100 PSI\u003c\/li\u003e\n\u003cli\u003eMax depth: 60m (197 ft)\u003c\/li\u003e\n\u003cli\u003eTemperature range °C: 1 ? 99 °C\u003c\/li\u003e\n\u003cli\u003eCable length: 1 meter\u003c\/li\u003e\n\u003cli\u003eInternal temperature sensor: No\u003c\/li\u003e\n\u003cli\u003eTime before recalibration: ~1 Year\u003c\/li\u003e\n\u003cli\u003eLife expectancy: ~2.5 Years +\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_probe.pdf\" target=\"_blank\"\u003eLab Grade pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-l-ph-probe.pdf\" target=\"_blank\"\u003eLEGACY Lab Grade probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph_soil.pdf\" target=\"_blank\"\u003eHow to measure the pH of soil\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-pH.zip\" target=\"_blank\"\u003eENV-40-pH 3D model (*step)\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-l-ph-probe.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42292846526655,"sku":"MLE04312","price":5800.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04312_4.jpg?v=1749882657"},{"product_id":"ezo-o2-embedded-oxygen-sensor","title":"EZO-O2™ Embedded Oxygen Sensor","description":"\u003cdiv\u003e\n\u003cdiv class=\"flex flex-grow flex-col max-w-full\"\u003e\n\u003cdiv data-message-id=\"dacd81ee-96a8-4c9f-94b0-2cbe7b0386d2\" data-message-author-role=\"assistant\" class=\"min-h-[20px] text-message flex flex-col items-start gap-3 whitespace-pre-wrap break-words [.text-message+\u0026amp;]:mt-5 overflow-x-auto\"\u003e\n\u003cdiv class=\"markdown prose w-full break-words dark:prose-invert dark\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Atlas Scientific gaseous oxygen sensor features a durable stainless steel enclosure, offering accurate measurements of oxygen concentrations from 0 to 420 ppt for both environmental monitoring and industrial applications. Pre-calibrated for immediate use, its stainless steel design guarantees resilience and dependable performance in tough conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe EZO-O2-S™ comes with:\u003cbr\u003eOne embedded oxygen sensor with stainless steel body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReads Gaseous O2\u003c\/li\u003e\n\u003cli\u003eRange 0 – 42% (2x atmospheric O2 levels)\u003c\/li\u003e\n\u003cli\u003eCalibration Factory calibrated\u003c\/li\u003e\n\u003cli\u003eResponse time 1 reading per second\u003c\/li\u003e\n\u003cli\u003eResolution 0.01\u003c\/li\u003e\n\u003cli\u003eAccuracy +\/- 0.01%\u003c\/li\u003e\n\u003cli\u003e(0.02 PPT)\u003c\/li\u003e\n\u003cli\u003eConnector 5 lead data cable\u003c\/li\u003e\n\u003cli\u003eCable length 1 meter\u003c\/li\u003e\n\u003cli\u003eData protocol UART \u0026amp; I2C\u003c\/li\u003e\n\u003cli\u003eDefault I2C Address 108 (0x6c)\u003c\/li\u003e\n\u003cli\u003eData format ASCII\u003c\/li\u003e\n\u003cli\u003eOperating voltage 3.3V – 5V\u003c\/li\u003e\n\u003cli\u003eLife expectancy ~3.5 years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-O2-S-datasheet.pdf\" target=\"_blank\"\u003eEZO-O2™ Stainless Steel Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-O2-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-O2-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-O2-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42292893843647,"sku":"MLE03304","price":6000.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE03304.jpg?v=1753513254"},{"product_id":"ezo-co2-embedded-carbon-dioxide-sensor","title":"Atlas EZO-CO2 Embedded Carbon Dioxide Sensor | EZO-CO2","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWith all the talk of Co2 these days, you would think it’s easy to detect. \u003c\/span\u003e\u003cspan\u003eBut Co2 only consists of 0.04% of the atmosphere meaning; it’s a trace gas that’s quite difficult to detect. The \u003cstrong\u003eAtlas Scientific EZO-CO2 sensor\u003c\/strong\u003e is a compact Non-Dispersive Infrared (NDIR) sensor that gets right to the point, giving you the Co2 readings in ppm. With internal temperature and humidity compensation, the Atlas Scientific EZO-CO2 sensor easily brings advanced sensing to your next project.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReads: Gaseous CO2\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: 0 − 10,000 ppm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration: Factory calibrated\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure: Atmosphere only\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 1 reading per second\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: 1 ppm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: (+\/- 5%) + (+\/- 50 ppm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnector: 5 lead data cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarmup time: 10 seconds\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable length: 1 meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData protocol: UART \u0026amp; I2C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDefault I2C address: 105 (0x69)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData format: ASCII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating voltage: 3.3V − 5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLife expectancy: ~5.5 years\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO_CO2_Datasheet.pdf\" target=\"_blank\"\u003eEZO-CO2™ Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.hackster.io\/atlasscientific\/arduino-co2-meter-c030ce\" target=\"_blank\"\u003eHow to build an Arduino CO2 meter\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-CO2-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-CO2-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-CO2-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-CO2.zip\" target=\"_blank\"\u003eEZO-CO2™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42292904132799,"sku":"MLE01317","price":13990.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE01317.jpg?v=1749718778"},{"product_id":"atlas-ph-10-00-ph-7-00-ph-4-00-calibration-solution-pouch-high-accuracy-calibration-solutions","title":"Atlas pH 10.00 pH 7.00 pH 4.00 Calibration Solution Pouch High accuracy calibration solutions","description":"\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003cbr\u003eAtlas Scientific pH calibration solutions are made using a four-stage process to ensure the highest accuracy.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003epH 10.00\u003c\/li\u003e\n\u003cli\u003e20ml each pouch\u003c\/li\u003e\n\u003cli\u003e±0.02 pH at 25°C\u003c\/li\u003e\n\u003cli\u003eWorks with any pH Probe\u003c\/li\u003e\n\u003cli\u003e2-year shelf life at room temperature\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003epH 7.00\u003c\/li\u003e\n\u003cli\u003e20ml each pouch\u003c\/li\u003e\n\u003cli\u003e±0.02 pH at 25°C\u003c\/li\u003e\n\u003cli\u003eWorks with any pH Probe\u003c\/li\u003e\n\u003cli\u003e2-year shelf life at room temperature\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003epH 4.00\u003c\/li\u003e\n\u003cli\u003e20ml each pouch\u003c\/li\u003e\n\u003cli\u003e±0.02 pH at 25°C\u003c\/li\u003e\n\u003cli\u003eWorks with any pH Probe\u003c\/li\u003e\n\u003cli\u003e2-year shelf life at room temperature\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Atlas pH 10.00","offer_id":43922087608511,"sku":"MLE03581","price":200.0,"currency_code":"PHP","in_stock":false},{"title":"Atlas pH 7.00","offer_id":43922087641279,"sku":"MLE03582","price":200.0,"currency_code":"PHP","in_stock":true},{"title":"Atlas pH 4.00","offer_id":43922087674047,"sku":"MLE03583","price":200.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/ph.jpg?v=1753516212"},{"product_id":"atlas-3-meter-bnc-male-to-bnc-female-extension-cable","title":"Atlas 3 Meter BNC male to BNC female Extension Cable | BNC-E3","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cbr\u003eThis 3 Meter BNC male to BNC female Extension Cable allows you to extend the length of your probes cable by 3 meters (10 feet), via BNC male\/female connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBNC male to BNC female\u003c\/li\u003e\n\u003cli\u003e3 meters (10')\u003c\/li\u003e\n\u003cli\u003e430 Stainless Steel\u003c\/li\u003e\n\u003cli\u003eRG179 cable\u003c\/li\u003e\n\u003cli\u003e75-ohm impedance\u003c\/li\u003e\n\u003cli\u003eFood safe\u003c\/li\u003e\n\u003cli\u003eMax Temperature Rating: 200° C\u003c\/li\u003e\n\u003cli\u003eJacket diameter: 0.100 inch +\/- 0.005\u003c\/li\u003e\n\u003cli\u003eWorks with all Atlas Scientific probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDocuments \u0026amp; Downloads\u003cbr\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/NSF-51-BNC-extension-cable.pdf\" target=\"_blank\" rel=\"noopener\"\u003eNSF\/ANSI 51 Statement of Conformity\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42903565533375,"sku":"MLE01657","price":749.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/sg-11134201-7rdxy-lyabxfcxacte96.jpg?v=1735812342"},{"product_id":"atlas-conductivity-calibration-k-1-0-set","title":"Atlas Conductivity Calibration K 1.0 Set 125ml (4oz) (12,880µS and 80,000µS) chem-EC-1.0","description":"\u003carticle class=\"lzd-article\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate of analysis, just email\u003cspan\u003e \u003c\/span\u003esupport\u003cspan\u003e \u003c\/span\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFor K 1.0 Calibration\u003c\/li\u003e\n\u003cli\u003e125ml (4oz)\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003cli\u003e2 year shelf life at room temperature\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli style=\"line-height: 1.7; text-align: left; text-indent: 0px;\"\u003e1x 12,880pS\u003c\/li\u003e\n\u003cli style=\"line-height: 1.7; text-align: left; text-indent: 0px;\"\u003e1x 80,000pS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42919357448383,"sku":"MLE03573","price":1099.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE03573.jpg?v=1753518688"},{"product_id":"ezo-ph-atlas-scientific-ezo-ph-circuit","title":"Atlas Scientific EZO™ pH Circuit | EZO-pH","description":"\u003carticle class=\"lzd-article\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAlthough it is a common measurement, accurately reading pH is very difficult. \u003cstrong\u003eAtlas Scientific’s EZO-pH\u003c\/strong\u003e circuit gives engineers the ability to read pH with the same accuracy and capabilities that were traditionally only found in expensive bench-top meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith an easy to use data protocol, simple command structure, and an easy to read datasheet engineers of any skill level will be able to add high accuracy pH readings to their next project quickly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReads: pH\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange:  0.001 − 14.000\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: 0.001\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/– 0.002\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 1 reading per sec\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupported probes: Any type \u0026amp; brand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration: 1, 2, 3 point\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemp. compensation: Yes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternational standard: ISO 10523 compliant (determination of pH)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData protocol: UART \u0026amp; I2C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDefault I2C address: 99 (0x63)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating voltage: 3.3V − 5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData format: ASCII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCircuit dimensions: 13.97mm x 20.16mm (0.55″ x 0.79″)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeight: 1.76 grams\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ pH Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ph-wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-pH-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-pH-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-pH-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D file:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph-footprint.zip\" target=\"_blank\"\u003eEZO™ pH Circuit Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-pH.zip\" target=\"_blank\"\u003eEZO™ pH Circuit 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstructable:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/DIY-PH-DOSING-PUMP\/\" target=\"_blank\"\u003epH Dosing Pump\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/MAKE-YOUR-OWN-PH-EC-MONITOR-WITH-LED-INDICATORS\/\" target=\"_blank\"\u003epH and Salinity Monitoring System with LEDs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42919358791871,"sku":"MLE00718","price":3000.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00718.jpg?v=1749716510"},{"product_id":"atlas-gravity-analog-temperature-kit-kit-304","title":"Atlas Scientific Surveyor™ Analog Temperature Kit | KIT-304","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"elementor-toggle-item\"\u003e\n\u003cdiv aria-labelledby=\"elementor-tab-title-6842\" role=\"region\" data-tab=\"2\" class=\"elementor-tab-content elementor-clearfix\" id=\"elementor-tab-content-6842\"\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003e\u003cem\u003e(Previously known as the Gravity Analog Temperature kit)\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePlatinum temperature sensors provide the highest level of stability and repeatability. The Atlas Scientific\u003cspan\u003e \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003eSurveyor™ Analog Temperature kit comes with the RTD meter and a Class-B platinum RTD probe. This kit provides everything you need to take highly stable and repeatable analog temperature readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis Temperature Probe can be \u003cem\u003e\u003cstrong\u003efully submerged \u003c\/strong\u003e\u003c\/em\u003ein fresh water or salt water, up to the SMA connector \u003cem\u003e\u003cstrong\u003eindefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower Consumption: 5 V = 0.9 mA I 3.3 V = 0.9 mA\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: -65 - 125 °C\u003c\/li\u003e\n\u003cli\u003eOperational Temperature: -40 - 50 °C\u003c\/li\u003e\n\u003cli\u003eVCC: 3.3 - 5.5 V\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 0.5 °C\u003c\/li\u003e\n\u003cli\u003eLife expectancy:  10 years\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-Temp-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog Temperature Sensor \/ Meter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/PT-STD-probe.pdf\" target=\"_blank\"\u003eStandard Temperature Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-RTD-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/PT-STD-probe.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RTD-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog Temperature Sensor \/ Meter 3D model (*step)\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e1x Gravity™ Analog Temperature Sensor \/ Meter\u003c\/li\u003e\n\u003cli\u003e1x Standard Temperature Probe\u003c\/li\u003e\n\u003cli\u003e1x jumper wire pack\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42919358988479,"sku":"MLE04090","price":2999.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04090.jpg?v=1749871746"},{"product_id":"atlas-ezo-conductivity-circuit","title":"Atlas EZO™ Conductivity Circuit | EZO-EC","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003eThe EZO Conductivity Circuit is a fundamental measurement of water chemistry. The Atlas Scientific EZO-EC Circuit reads conductivity, salinity, and TDS (PPM). Embedding this module into your machine gives you access to the same accuracy and functionality found in costly bench-top conductivity meters. If you need accurate readings that you can rely on, the EZO-EC circuit is the drop-in solution you have been looking for.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReads: Conductivity = µS\/cm | Total dissolved solids = ppm | Salinity = PSU (ppt) 0.00 - 42.00 | Specific gravity (sea water only) = 1.00 - 1.300\u003c\/li\u003e\n\u003cli\u003eRange: 0.07 - 500,000+ µS\/cm\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 2%\u003c\/li\u003e\n\u003cli\u003eResponse time: 1 reading per sec\u003c\/li\u003e\n\u003cli\u003eSupported probes: K 0.1 - K 10 any brand\u003c\/li\u003e\n\u003cli\u003eCalibration: 2 or 3 point\u003c\/li\u003e\n\u003cli\u003eTemp. compensation: Yes\u003c\/li\u003e\n\u003cli\u003eData protocol: UART and I2C\u003c\/li\u003e\n\u003cli\u003eDefault I2C address: 100 (0x64)\u003c\/li\u003e\n\u003cli\u003eOperating voltage: 3.3 - 5 V\u003c\/li\u003e\n\u003cli\u003eData format: ASCII\u003c\/li\u003e\n\u003cli\u003eWeight: 1.77 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\"\u003eConductivity Wiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/MAKE-YOUR-OWN-PH-EC-MONITOR-WITH-LED-INDICATORS\/\" target=\"_blank\"\u003epH and Salinity Monitoring System with LEDs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42919359152319,"sku":"MLE03419","price":7099.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE03419_4.jpg?v=1753517771"},{"product_id":"atlas-gravity-analog-ph-sensor-meter","title":"Atlas Surveyor™ Analog pH Sensor | Meter","description":"\u003carticle class=\"lzd-article\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003e(Previously known as the Gravity Analog pH Sensor \/ Meter)\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIf you are building a machine that requires pH measuring capabilities, but you only need the accuracy found in a low-cost handheld pH meter, the Atlas Scientific Surveyor™ pH meter might be for you. Simple to use and straight to the point, the Atlas Scientific Surveyor™ pH meter outputs an analog signal that’s easy to read.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReads: pH\u003c\/li\u003e\n\u003cli\u003eRange: 0.1 − 14.0\u003c\/li\u003e\n\u003cli\u003eResolution: 0.1\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/– 0.2\u003c\/li\u003e\n\u003cli\u003eResponse Time: Continuous analog output\u003c\/li\u003e\n\u003cli\u003eSupported probes: Any type \u0026amp; brand\u003c\/li\u003e\n\u003cli\u003eCalibration: Optional\u003c\/li\u003e\n\u003cli\u003eTemp Compensation: No (unnecessary)\u003c\/li\u003e\n\u003cli\u003eData Protocol: Analog 2.7 − 0.2V\u003c\/li\u003e\n\u003cli\u003eDimensions: 54mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 15 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-pH-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog pH Sensor \/ Meter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-pH-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/ARDUINO-PH-METER\/\" target=\"_blank\"\u003eHow to build an Arduino pH meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog pH Sensor \/ Meter 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e(4) standoffs and screws,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e(1) 3 pin jumper cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":42919359512767,"sku":"MLE01658","price":1499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE01658.jpg?v=1750313683"},{"product_id":"atlas-male-bnc-to-male-sma-connector","title":"Atlas Male BNC to Male SMA connector 1pc","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e This is sold per piece.\u003cbr\u003e\u003cbr\u003eThe Atlas Scientific Male BNC to Male SMA Connector provides a convenient solution for adapting connections, facilitating the integration of Atlas Scientific sensors with SMA interfaces, and ensuring seamless compatibility in a variety of electronic setups.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures and Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1pc of Male BNC to Male SMA Connector\u003c\/li\u003e\n\u003cli\u003e75-ohm impedance\u003c\/li\u003e\n\u003cli\u003eWorks with all Atlas Scientific probes\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg src=\"https:\/\/cf.shopee.ph\/file\/sg-11134202-7rcc0-lt284bt48qix6d\"\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43081516843199,"sku":"MLE04290","price":299.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/sg-11134201-7rdwn-lya9qdt1eqeg14.jpg?v=1735811978"},{"product_id":"atlas-electrically-isolated-ezo-carrier-board","title":"Atlas Electrically Isolated EZO™ Carrier Board | ISCCB-2","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis carrier board utilizes the newest isolation technology, giving us the ability to put isolation into smaller footprint circuits. The \u003cstrong\u003eElectrically isolated EZO™ carrier board\u003c\/strong\u003e is an efficient way to connect to one Atlas Scientific circuit to your CPU, eliminating the need for a bread board and external isolator. The five pins on top are left open for you to decide how to connect it to your system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eData input: UART or I2C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoltage input: 3.0V − 5.0V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProbe connector: Female SMA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eCurrent consumption: 5V – 28 mA, \u003c\/span\u003e\u003cspan\u003e3.3V – 22 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower saving mode (OFF pin): 2.6mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrier Board dimensions: 56.2mm x 32mm (2.2″ x 1.2″)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeight: 25 grams\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board Gen 2 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D file:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Electrically-Isolated-EZO-Carrier-Board.zip\" target=\"_blank\"\u003eElectrically Isolated EZO™ Carrier Board 3D model (STEP)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e(4) standoffs \u0026amp; screws,\u003c\/li\u003e\n\u003cli\u003e(1) 5 pin jumper cable and\u003c\/li\u003e\n\u003cli\u003e(1) 5 pin male header\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43081516974271,"sku":"MLE03420","price":3449.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE03420.jpg?v=1749794151"},{"product_id":"atlas-gravity-analog-orp-sensor-meter","title":"Atlas Scientific Surveyor™ Analog ORP Sensor \/ Meter | SRV-ORP","description":"\u003cdiv\u003e\n\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e(Previously known as the Gravity Analog ORP Sensor \/ Meter)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eEvery project is different; sometimes, you need high-accuracy digital readings. And other times, you only need a basic analog output. For those of you looking to add ORP measurements to your device but want something simple, the Atlas Scientific Gravity ORP Meter\/Sensor is for you. This low-cost ORP meter gives you the same capabilities found in basic hand-held meters, with an easy way of capturing the data.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReads: ORP\u003c\/li\u003e\n\u003cli\u003eRange: -1500mV − 1500mV\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/– 1mV\u003c\/li\u003e\n\u003cli\u003eResponse time: Continuous analog output\u003c\/li\u003e\n\u003cli\u003eSupported probes: Any type \u0026amp; brand\u003c\/li\u003e\n\u003cli\u003eCalibration: Optional\u003c\/li\u003e\n\u003cli\u003eTemp. compensation: No (unnecessary)\u003c\/li\u003e\n\u003cli\u003eData protocol: Analog 0 − 3V\u003c\/li\u003e\n\u003cli\u003eSurveyor™ dimensions: 56.2mm x 32mm (2.2″ x 1.2″)\u003c\/li\u003e\n\u003cli\u003eWeight: 15 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Surveyor-ORP-datasheet.pdf\" target=\"_blank\"\u003eSurveyor™ Analog ORP Sensor \/ Meter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-ORP-ardunio-code.pdf\" target=\"_blank\"\u003eArduino Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP-Gravity.zip\" target=\"_blank\"\u003eSurveyor™ Analog ORP Sensor \/ Meter 3D model (*step)\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/surveyor-ORP-ardunio-code.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e(4) standoffs and screws\u003c\/li\u003e\n\u003cli\u003e(1) 3 pin jumper cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43081517105343,"sku":"MLE04055","price":2390.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04055.jpg?v=1749866572"},{"product_id":"atlas-conductivity-calibration-k-10-set-125ml","title":"Atlas Conductivity Calibration K 10 Set 125ml (4oz) 12,880µS and 150,000µS | chem-EC-10","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eHigh-accuracy sensors require high-accuracy calibration solutions.\u003cbr\u003e\u003cbr\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate of analysis, just email support with the lot number and expiration date of your calibration solution.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFor K 10 Calibration\u003c\/li\u003e\n\u003cli\u003e125ml (4oz)\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003cli\u003e2-year shelf life at room temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Conductivity-k10-SDS.pdf\" target=\"_blank\"\u003eConductivity Calibration K 10 Set SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x 12,880µS\u003c\/li\u003e\n\u003cli\u003e1x 150,000µS\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43081522741439,"sku":"MLE04054","price":1790.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04054.jpg?v=1749865597"},{"product_id":"atlas-mini-conductivity-probe-k-1-0-env-20-ec-k1-0","title":"Atlas Mini Conductivity Probe K 1.0 | ENV-20-EC-K1.0","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWorks just as good as the full-size conductivity probe, only smaller. What else is there to say. \u003c\/span\u003e\u003cspan\u003eBecause conductivity probes don’t have any electrolyte that gets depleted, they only need to be calibrated during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReads: Conductivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: 5 − 200,000 μS\/cm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/ – 2%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 90% in 1s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range °C: 1 − 110 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax pressure: 3,447 kPa (500PSI)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax depth: 352m (1,157 ft)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnector: Male SMA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable length: 1 meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal temperature sensor: No\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTime before recalibration: ~10 years\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLife expectancy: ~10 years\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_EC_K_1.0_probe.pdf\" target=\"_blank\"\u003eMini Conductivity Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-Mini_EC_K_1.0_probe.pdf\" target=\"_blank\"\u003eLEGACY Mini Conductivity Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ec_soil.pdf\" target=\"_blank\"\u003eHow to measure the conductivity of soil\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-20-EC-K1.zip\" target=\"_blank\"\u003eENV-20-EC-K1.0 3D model (*step)\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-Mini_EC_K_1.0_probe.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43287132569791,"sku":"MLE04315","price":6499.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04315.jpg?v=1749884297"},{"product_id":"atlas-i2c-toggler-i2c-tog","title":"Atlas I2C Toggler | I2C-TOG","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEasily switch between UART \u0026amp; I2C with the press of a button:\u003cbr\u003e1. Select EZO™ circuit type\u003cbr\u003e2. Insert your EZO™ circuit or EZO™ device\u003cbr\u003e3. Plug I2C Toggler into USB port\/cable\u003cbr\u003e4. Press and hold button for ~1 second\u003cbr\u003e5. Release after color change:\u003cbr\u003e\u003cbr\u003eBlue = I2C\u003cbr\u003eGreen = UART\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2C Toggler does not come with any EZO™ class circuits or devices.\u003c\/li\u003e\n\u003cli\u003eDimensions: 12mm x 49mm (0.47? x 1.9?)\u003c\/li\u003e\n\u003cli\u003eWeight: 1.98 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.whiteboxes.ch\/docs\/i2c-toggler\/#\/\" target=\"_blank\"\u003eI2C Toggler Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43696845815999,"sku":"MLE04439","price":849.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04439.jpg?v=1749887602"},{"product_id":"atlas-gen-3-lab-grade-ph-probe-env-40-ph","title":"Atlas Gen 3 Lab Grade pH Probe | ENV-40-pH","description":"\u003cdiv\u003e\n\u003cp\u003eDescription\u003cbr\u003e\nThis Atlas Scientific Lab Grade pH probe is our highest accuracy pH probe. The internal double junction lets you read the pH of protein-rich solutions without damaging the probe. The green Vanadium III tip is a hydrogen amplifier, reducing noise and increasing reading stability. A Tyvek™ junction connects the pH probe to the outside world. Because Tyvek™ resists water flow, the internal electrolyte is held in the probe longer, leading to less frequent recalibrations.\u003cbr\u003e\n\u003cbr\u003e\nSpecifications\u003cbr\u003e\n\u003cbr\u003e\nDouble junction\u003cbr\u003e\nsilver \/ silver chloride\u003cbr\u003e\nReads pH\u003cbr\u003e\nRange 0 ? 14\u003cbr\u003e\nResolution +\/- 0.001\u003cbr\u003e\nAccuracy +\/- 0.002\u003cbr\u003e\nResponse time 95% in 1s\u003cbr\u003e\nTemperature range °C -5 ? 99 °C\u003cbr\u003e\nMax pressure 100 PSI\u003cbr\u003e\nMax depth 70m (230 ft)\u003cbr\u003e\nConnector Male SMA \/ Male BNC (optional)\u003cbr\u003e\nCable length 1 meter\u003cbr\u003e\nInternal temperature sensor No\u003cbr\u003e\nTime before recalibration ~1 Year\u003cbr\u003e\nLife expectancy ~2.5 Years +\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43696843620543,"sku":"MLE04793","price":4999.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/sg-11134201-7rdw6-lyd4vh5vkdbof6.jpg?v=1735811396"},{"product_id":"atlas-ezo-rtd-temperature-circuit-ezo-rtd","title":"Atlas Scientific EZO™ RTD Temperature Circuit | EZO-RTD","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThere is no shortage of temperature probes out there, and the most accurate of all is the platinum RTD probe. But, converting the resistance of platinum to an actual temperature is unusually complicated. Fortunately, the \u003cstrong\u003eAtlas Scientific EZO-RTD Circuit\u003c\/strong\u003e makes taking high accuracy readings from a platinum RTD probes easy. The EZO-RTD Circuit can work with any class of 2, 3, or 4 wire platinum RTD probes and has a sensing range of -126.000 °C to +1,254 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRTD: Resistance Temperature Detector\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReads: Temperature\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: -126.000 °C − 1254 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: 0.001\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/– (0.1 + 0.0017 x ̊C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 1 reading per sec\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupported probes: Any type \u0026amp; brand PT-100 or PT-1000 RTD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration: Single point\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature output: °C, °K, or °F\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData protocol: UART \u0026amp; I2C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDefault I2C address: 102 (0x66)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating voltage: 3.3V − 5.5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData format: ASCII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOnboard Data Logger: 50 Readings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical Isolation: not needed    \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCircuit dimensions: 13.97mm x 20.16mm (0.55″ x 0.79″)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eWeight: 1.76 grams\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO_RTD_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ RTD Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-rtd-Wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBasic Sample Code:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-RTD-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-RTD-Sample-Code.pdf.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-RTD-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-RTD-Sample-Code.pdf.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D File:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-RTD.zip\" target=\"_blank\"\u003eEZO™ RTD Circuit 3D model (*step)\u003c\/a\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLibrary:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstructable:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/AUTOMATIC-TEMPERATURE-COMPENSATION-OF-THE-EZO-EC-S\/\" target=\"_blank\"\u003eAuto Temp Compensation for Conductivity\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x EZO™ RTD Temperature Circuit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43473641144511,"sku":"MLE01588","price":2900.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE01588_2.jpg?v=1749720955"},{"product_id":"atlas-pre-assembled-female-bnc-connector","title":"Atlas Pre-Assembled Female BNC | com-101","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Atlas Scientific Pre-Assembled Female BNC simplifies sensor integration by providing a ready-to-use BNC connector, streamlining the connection process, and ensuring a reliable and efficient interface for Atlas Scientific sensors.\u003cbr\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePre-Assembled Female BNC Connector\u003c\/li\u003e\n\u003cli\u003eLow Profile\u003c\/li\u003e\n\u003cli\u003eIncludes washer and nut\u003c\/li\u003e\n\u003cli\u003eDesigned for RF applications\u003c\/li\u003e\n\u003cli\u003eRight angle\u003c\/li\u003e\n\u003cli\u003e50 ohm impedance\u003c\/li\u003e\n\u003cli\u003eDesigned to be easily connected to a breadboard for rapid development\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43500432294079,"sku":"MLE04056","price":99.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04056_2.jpg?v=1749867580"},{"product_id":"atlas-conductivity-calibration-k-1-0-set-4-pouches","title":"Atlas Conductivity Calibration K 1.0 Set (4 pouches)","description":"\u003ch2\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eHigh accuracy sensors require high accuracy calibration solutions.\u003c\/p\u003e\n\u003cp\u003eAtlas Scientific conductivity calibration solutions are made using a six-stage process to ensure the highest accuracy. If you need a certificate of analysis, just email\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:Support@Atlas-Scientific.com\" rel=\"noopener noreferrer\" target=\"_blank\"\u003esupport\u003cspan\u003e \u003c\/span\u003e\u003c\/a\u003ewith the lot number and expiration date of your calibration solution.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e20ml each pouch\u003c\/li\u003e\n\u003cli\u003eFor K 1.0 Calibration\u003c\/li\u003e\n\u003cli\u003e2-year shelf life at room temperature\u003c\/li\u003e\n\u003cli\u003eStandardized against NIST-certified references\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Conductivity-k1.0-SDS.pdf\" target=\"_blank\"\u003eConductivity Calibration K 1.0 Set SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2x (12,880µS)\u003c\/li\u003e\n\u003cli\u003e2x (80,000µS)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43516577415359,"sku":"MLE04316","price":1249.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/Atlas_161b028d-5c10-4ec4-9cad-b116171ef2ed.jpg?v=1749885784"},{"product_id":"atlas-scientific-industrial-ph-probe-env-50-ph","title":"Atlas Scientific Industrial pH Probe | ENV-50-pH","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for industrial process control, the Atlas Scientific industrial pH probe has all the capabilities of our lab-grade pH probe and more\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBecause the probe is larger, it holds more internal electrolyte. This means it has a life expectancy almost twice as long as our Lab Grade probe. Its thick Ryton body is chemically inert and virtually indestructible. Unlike traditional pH probes that have a glass bulb at its tip, this probe has a flat sensing area. That means that you never have to worry about the glass breaking off into your liquid. And we didn’t even mention the 3\/4″ NPT threaded body or internal temperature sensor!\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDouble junction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003esilver \/ silver chloride    \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReads: pH\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: 0 − 14\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: +\/- 0.001\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/- 0.002\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 95% in 1s\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range °C: 1 − 99 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax pressure: 100 PSI\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax depth: 70m (230′)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnector: SMA or Tinned leads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable length: 3 meters (9.8′)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal temperature sensor: Yes (PT-1000)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTime before recalibration: ~1 Year\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eLife expectancy: ~4 Years \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheets:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IpH_probe_with_temp.pdf\" target=\"_blank\"\u003epH Industrial Probe with Temp Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-i-pH-probe.pdf\" target=\"_blank\"\u003eLEGACY pH Industrial Probe Datasheet\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDocuments:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTools:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3D Files:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43556353638591,"sku":"MLE00717","price":11499.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE00717_2.jpg?v=1749715428"},{"product_id":"atlas-industrial-dissolved-oxygen-probe-env-50-do","title":"Atlas Scientific Industrial Dissolved Oxygen Probe | ENV-50-DO","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eWhen you need long term readings from a probe that’s almost impossible to break, the \u003cstrong\u003eAtlas Scientific Industrial Dissolved Oxygen probe\u003c\/strong\u003e is what you need. The probe holds a lot of electrolyte so it will last for a long time before needing reconditioning. The built-in PT-1000 temperature sensor and threaded body reduces the need for excess parts and makes it easy to install in a pipe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis D.O. Probe can be \u003cem\u003e\u003cstrong\u003efully submerged\u003c\/strong\u003e\u003c\/em\u003e in fresh water or salt water, up to the SMA connector\u003cem\u003e\u003cstrong\u003e indefinitely.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReads: Dissolved Oxygen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: 0 − 100 mg\/L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/– 0.05 mg\/L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: ~0.1 mg\/L\/per sec\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemperature range °C: 1 − 99 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax pressure: 300 PSI\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMax depth: 212m (694 ft)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eConnector: Tinned leads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCable length: 3 Meters (10′)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal temperature sensor: Yes (PT-1000)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTime before recalibration: ~1 Year\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLife expectancy: ~4 Years\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance: ~18 Months\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-DO-probe.pdf\" target=\"_blank\"\u003eIndustrial Dissolved Oxygen Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-Industrial-DO-probe.pdf\" target=\"_blank\"\u003eLegacy Industrial Dissolved Oxygen Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Gen3_Industrial-DO.zip\" target=\"_blank\"\u003eENV-50-DO 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Atlas Scientific Industrial Dissolved Oxygen Probe\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43556353966271,"sku":"MLE03569","price":29990.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE03569.jpg?v=1749795110"},{"product_id":"atlas-industrial-conductivity-probe-k-1-0-env-50-ec-k1-0","title":"Atlas Industrial Conductivity Probe K 1.0 | ENV-50-EC-K1.0","description":"\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 500px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReads\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 ? 200,000?S\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range °C\u003c\/td\u003e\n\u003ctd\u003e0 ? 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax pressure\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax depth\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e3 meters (10?)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe fitting\u003c\/td\u003e\n\u003ctd\u003e3\/4? threaded NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Temperature sensor\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime before recalibration\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife expectancy\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43556355080383,"sku":"MLE04269","price":20000.0,"currency_code":"PHP","in_stock":false}]},{"product_id":"atlas-ezo-dissolved-oxygen-circuit-ezo-do","title":"Atlas Scientific EZO™ Dissolved Oxygen Circuit | EZO-DO","description":"\u003ch2\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAccurately calculating the D.O. of water is quite difficult. Once all the mathematical calculations are done, it takes hundreds of chemical titration tests to confirm that the readings are correct over the full scale. The process is agonizing. Fortunately, you don’t have to do any of that. The Atlas Scientific EZO-DO Circuit gives you accurate D.O. readings in Mg\/L and percent saturation. Using its temperature, salinity, and pressure compensation features, you can be sure the readings are correct no matter where in the world you are.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReads: Dissolved Oxygen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRange: 0.01 − 100+ mg\/L, 0.1 − 400+ % saturation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: +\/– 0.05 mg\/L\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResponse time: 1 reading per sec\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSupported probes: Any galvanic probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration: 1 or 2 point\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTemp. compensation: Yes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSalinity compensation: Yes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure compensation: Yes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternational standard: ISO 5814 compliant (determination of dissolved oxygen)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData protocol: UART \u0026amp; I2C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDefault I2C address: 97 (0x61)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating voltage: 3.3V − 5V\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData format: ASCII\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCircuit dimensions: 13.97mm x 20.16mm (0.55″ x 0.79″)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeight: 1.77 grams\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eDocuments \u0026amp; Downloads:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul id=\"product-files-links\"\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_EZO_Datasheet.pdf\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-DO-Sample-Code.pdf\" target=\"_blank\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-DO-sample-code.pdf\" target=\"_blank\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved_oxygen-footprint.zip\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli class=\"product-files-links-item\"\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-DO.zip\" target=\"_blank\"\u003eEZO™ Dissolved Oxygen Circuit 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePart List: \u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x EZO™ Dissolved Oxygen Circuit\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas","offers":[{"title":"Default Title","offer_id":43556355702975,"sku":"MLE04057","price":3000.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/files\/MLE04057.jpg?v=1749868896"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0531\/3419\/6927\/collections\/atlas.jpg?v=1721193539","url":"https:\/\/makerlab.ph\/collections\/atlas-scientific-philippines.oembed?page=2","provider":"Makerlab PH","version":"1.0","type":"link"}